LabJack T-series DAQ

LabJack T-series DAQ

Local
github.comScience & Education23Updated 5w ago

About LabJack T-series DAQ

LabJack T-series DAQ is an MCP server for LabJack T4, T7/T7-Pro, and T8 data-acquisition devices, using the LJM library. It reads analog and digital inputs, thermocouples, and waveforms, and can set outputs; hardware verification is not yet reported.

Key features

  1. 01Read analog inputs and device temperature
  2. 02Read thermocouple measurements
  3. 03Inspect digital input states
  4. 04Stream and save waveforms
  5. 05Set DAC and digital outputs

Use cases

  1. 01Read analog channels and check for floating inputs
  2. 02Acquire waveforms at a set rate and calculate statistics
  3. 03Read a thermocouple and track temperature changes
  4. 04Set a DAC output and check its loopback reading

MCP support

The MCP server exposes LabJack device information, analog and digital readings, thermocouple measurements, and streaming tools, along with controls for DAC and digital outputs.

Configuration

Local server config is the same for every client. Copy it into your client’s MCP config file.

mcp.json · Universal config
{
"mcpServers": {
"k-dense-ai-labmcp-labjack": {
"command": "uvx",
"args": [
"labmcp-labjack"
],
"env": {
"LABMCP_ADDRESS": "<LABMCP_ADDRESS>",
"LABMCP_SIMULATE": "<LABMCP_SIMULATE>",
"LABMCP_READ_ONLY": "<LABMCP_READ_ONLY>",
"LABMCP_LIMITS": "<LABMCP_LIMITS>"
}
}
}
}
Run commanduvx labmcp-labjack
Environment variables to set
LABMCP_ADDRESSInstrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
LABMCP_SIMULATESet to 1 to use the built-in simulator (no hardware)
LABMCP_READ_ONLYSet to 1 to disable all state-changing tools
LABMCP_LIMITSSafety limit overrides, e.g. max_temperature_c=80

Local servers need a runtime on your machine (e.g. Node.js 18+). Config file locations differ by client; see your client’s docs.

Packages
pypilabmcp-labjack0.1.3

Tools

12

Saved tool list · updated 2w ago

This tool takes no parameters.

Details

From the project README

LabJack T-series DAQ — MCP Server

Let an AI agent read analog inputs, stream waveforms, read thermocouples, check digital lines and (with your permission) set DACs and digital outputs on LabJack T4, T7/T7-Pro and T8 DAQ devices through LabJack's official LJM library.

Packagelabmcp-labjack
InstrumentsLabJack T4, T7, T7-Pro, T8 (and their OEM versions)
InterfacesUSB, Ethernet, WiFi (T7-Pro)
ProtocolLJM library + T-series Modbus register map (T-Series Datasheet, register map ljm_constants.json, labjack-ljm Python wrapper)
Status🧪 simulated: tested against a simulated LJM backend, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-labjack --simulate --check
uvx labmcp-labjack --simulate --option sim_model=T8 --check     # T4, T7, T7-Pro (default) or T8

The simulator wires a 2 V / 10 Hz sine to AIN0, a thermistor divider (~2.5 V) to AIN1, DAC0 back into AIN2, an LM34 cold-junction sensor to AIN3, and a ~37 °C thermocouple to AIN0-AIN3 when the thermocouple feature is used. Other inputs are grounded.

Connect your LabJack

  1. Install LJM (the native library and USB driver) from labjack.com/support/software/installers/ljm. The labjack-ljm Python package is installed automatically with this server, but it needs that native library.
  2. Close other LabJack software (Kipling, LJLogM, LJStreamM). A device can only be claimed by one process at a time over USB.
  3. Test the connection:
    uvx labmcp-labjack --check                                  # first LabJack found
    uvx labmcp-labjack --address 470012345 --check              # by serial number
    uvx labmcp-labjack --address 192.168.1.207 --option connection_type=ETHERNET --check
    uvx labmcp-labjack --option device_type=T4 --check          # only open a T4
    
    --address is the LJM identifier: a serial number, an IP address, a device name, or ANY (the default).

Add to your MCP client

Claude Code

claude mcp add labjack -- uvx labmcp-labjack --address 470012345

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "labjack": {
      "command": "uvx",
      "args": ["labmcp-labjack", "--address", "470012345"]
    }
  }
}

Add --read-only to allow measurements but block the DAC and digital-output tools (set_outputs_safe stays available). Add --option safe_dio=FIO0,FIO1 to make set_outputs_safe always release those lines, even if another program drove them. For other clients, generate the snippet with uvx labmcp config labjack --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info👁 readIdentify the connected LabJack (model, serial, firmware, connection) and list what it offers: analog inputs, valid input ranges, resolution indices, DAC range, digital lines and stream rate. Call this before configuring channels.
read_analog_inputs👁 readRead one or more analog inputs once (command-response) and return volts.
read_device_temperature👁 readRead the LabJack's internal temperature sensor (°C, about ±2 °C) and the estimated ambient air temperature. On the T8 also returns the sensor next to each AIN terminal. Cannot be read while a stream is running.
read_digital_inputs👁 readReport the logic level and direction (input/output/analog) of digital I/O lines.
read_thermocouple👁 readRead a thermocouple with the T7/T8 AIN thermocouple extended feature (types B, C, E, J, K, N, R, S, T) and return °C with the measured voltage and cold-junction temperature.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_digital_output⚠️ hazardMake a digital line an output and drive it high (3.3 V) or low (0 V).
set_outputs_safe🛑 safetyPut the outputs in a safe state: stop any stream, set DAC0 and DAC1 to 0 V, and release every digital line this server drove (plus the safe_dio option lines) to input - or drive them low with dio_mode='low'. Use when finished or if anything looks wrong.
stream_analog👁 readAcquire a hardware-timed waveform on one or more analog inputs (LJM stream mode) and return per-channel statistics plus a downsampled waveform; optionally save everything to CSV.
write_dac⚠️ hazardSet an analog output (DAC0/DAC1) to a DC voltage. The output stays at this value until changed or set_outputs_safe is called.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every LJM register read and write.

Safety limits

LimitDefaultMeaning
max_dac_voltage_v5 VHighest DAC voltage an agent may set (hardware: T4/T7 0-5 V, T8 0-10 V)
max_stream_duration_s60 sLongest hardware-timed stream
max_scan_rate_hz10 000 HzHighest stream scan rate (the device maximum still applies)

Override at launch, e.g. --limit max_dac_voltage_v=2.5. Limits are checked before anything is sent. Streams are also capped at 2 million samples in total.

Example prompts

  • "Read AIN0-AIN3 on the ±1 V range and tell me which channels look like they are floating."
  • "Stream AIN0 and AIN1 at 5 kHz for 2 seconds, give me the RMS and peak-to-peak of each, and save the data to ~/data/run12.csv."
  • "Read the type K thermocouple on AIN2 every 10 seconds for a minute and tell me whether it is still warming up."
  • "Set DAC0 to 1.25 V, then check the loopback on AIN2 and report the error in millivolts."
  • "Which digital lines are outputs right now, and what level are they at?"
  • "We're done — put all the outputs back in a safe state."

Notes

  • Model differences are enforced. Valid input ranges (AIN#_RANGE) and resolution indices come from LabJack's register map: T7 ±10/±1/±0.1/±0.01 V and index 0-8 (T7-Pro 0-12, but 9-12 cannot stream); T8 ±11 … ±0.018 V and index 0-16 (one index shared by all inputs); T4 fixed ranges (AIN0-3 ±10 V, AIN4-11 0-2.5 V) and index 0-5. DAC range: T4/T7 0-5 V, T8 0-10 V.
  • Settings persist. Range, resolution and differential settings made by read_analog_inputs stay on the device until changed or power-cycled. Omitted settings are left as they are; every reading reports what it was measured against (GND, the T7 negative input, or the T8's isolated terminal).
  • Reading digital lines never changes their direction. read_digital_inputs uses the DIO_STATE/DIO_DIRECTION bitmasks. (Reading a single-line register such as FIO3 would switch that line to input.)
  • T4 flexible I/O. AIN4-AIN11 share terminals with FIO4-EIO3. The server refuses to read those AINs while the line is a digital output, because the read would switch it to analog and release whatever it drives.
  • set_outputs_safe default is input, the T-series power-up state (input with pull-up). If an attached relay board treats a pulled-up input as "on", use dio_mode="low" instead.
  • Thermocouples use the AIN extended feature (AIN#_EF_INDEX 20-30). With cjc="internal" the CJC register is set to its documented default TEMPERATURE_DEVICE_K (address 60052), which the T8 firmware maps to each channel's own terminal sensor (TEMPERATURE#_CAPTURE); cjc="lm34" uses LabJack's LM34 conversion (55.56 K/V, 255.37 K). An open input returns valid=false (the device reports -9999).
  • Streams follow LabJack's stream_basic.py example (internal clock, no trigger, auto settling). While a stream runs, command-response analog reads are blocked by the device. Skipped scans (buffer overflow) are reported and left empty. set_outputs_safe does not wait for a running stream: it stops it at the next read (the partial result is returned with aborted: true). A stream runs at 1 scan/s or faster (so that stop is prompt) and always takes at least two scans; that real duration is what the max_stream_duration_s limit checks. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost; save_path must be a new .csv file (an existing file is never overwritten, and the path is checked before streaming).
  • Importing the LJM wrapper prints to stdout if the native library is missing. The server redirects that import so the MCP stdio channel is never corrupted, and reports a clear install hint instead.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Comments

Markdown supported