Lake Shore Temperature Controller

Lake Shore Temperature Controller

Local
github.comScience & Education23Updated 5w ago

About Lake Shore Temperature Controller

An MCP server for laboratories using Lake Shore Cryotronics 335, 336, and 350 temperature controllers. It provides sensor readings, heater controls, and temperature-stability waits through several instrument interfaces, with safety limits for heating and setpoints; hardware verification is not yet reported.

Key features

  1. 01Read sensor temperatures and heater status
  2. 02Set temperature, ramps, heater range, and PID
  3. 03Wait for temperature stability conditions
  4. 04Turn off all heaters and inspect command logs
  5. 05Connect over USB, Ethernet, or GPIB

Use cases

  1. 01Check cryostat sensor readings
  2. 02Ramp temperature and wait for stability
  3. 03Inspect and adjust PID loop settings
  4. 04Turn off all heaters when issues arise

MCP support

As an MCP server, it exposes tools for temperature readings, heater status, setpoint and control adjustments, stability waits, and emergency heater shutdown to MCP clients.

Configuration

Local server config is the same for every client. Copy it into your client’s MCP config file.

mcp.json · Universal config
{
"mcpServers": {
"k-dense-ai-labmcp-lakeshore": {
"command": "uvx",
"args": [
"labmcp-lakeshore"
],
"env": {
"LABMCP_ADDRESS": "<LABMCP_ADDRESS>",
"LABMCP_SIMULATE": "<LABMCP_SIMULATE>",
"LABMCP_READ_ONLY": "<LABMCP_READ_ONLY>",
"LABMCP_LIMITS": "<LABMCP_LIMITS>"
}
}
}
}
Run commanduvx labmcp-lakeshore
Environment variables to set
LABMCP_ADDRESSInstrument address, e.g. serial:///dev/ttyUSB0 or tcp://192.168.1.50:5025
LABMCP_SIMULATESet to 1 to use the built-in simulator (no hardware)
LABMCP_READ_ONLYSet to 1 to disable all state-changing tools
LABMCP_LIMITSSafety limit overrides, e.g. max_temperature_c=80

Local servers need a runtime on your machine (e.g. Node.js 18+). Config file locations differ by client; see your client’s docs.

Packages
pypilabmcp-lakeshore0.1.3

Tools

11

Saved tool list · updated 2w ago

This tool takes no parameters.

Details

From the project README

Lake Shore Temperature Controller — MCP Server

Let an AI agent read every sensor on your cryostat, check heater status, set setpoints, ramps, heater ranges and PID values, wait for the temperature to settle, and switch all heaters off on Lake Shore Cryotronics Model 335, 336 and 350 temperature controllers.

Packagelabmcp-lakeshore
InstrumentsModel 335 (2 inputs, 2 outputs), Model 336 (4 inputs, 4 outputs), Model 350 (4 inputs, 4 outputs)
InterfacesUSB (virtual COM port), Ethernet (336 and 350, TCP port 7777), IEEE-488 (GPIB via VISA)
ProtocolLake Shore ASCII commands, chapter 6 of the Model 336 (rev. 2.3), Model 335 (rev. 1.6) and Model 350 (rev. 1.7) user's manuals
Status🧪 simulated: tested against a wire-level simulator with a thermal model, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-lakeshore --simulate --check
uvx labmcp-lakeshore --simulate --option sim_model=350 --option sim_speed=20 --check

The simulator models a small cryostat at 4.2 K: a stage (inputs A diode and C Cernox-like, heated by output 1) and a sample (input B Pt-100, heated by output 2), with Lake Shore's PID law and setpoint ramping. sim_speed makes simulated time run faster than real time.

Connect your controller

The model is detected from *IDN?; other Lake Shore models (325, 331, 340, 372, ...) are refused.

  1. Pick the interface in the controller's Interface menu (only one remote interface is active at a time).
  2. USB: install the Lake Shore USB driver (Windows Update, or lakeshore.com). The port runs at a fixed 57600 baud, 7 data bits, odd parity, 1 stop bit; the server sets this automatically.
  3. Ethernet (336, 350): configure the IP address on the front panel; the command port is TCP 7777 (two connections at most).
  4. Test the connection:
    uvx labmcp-lakeshore --address /dev/ttyACM0 --check          # Linux
    uvx labmcp-lakeshore --address /dev/tty.usbmodemXXXX --check # macOS
    uvx labmcp-lakeshore --address COM5 --check                  # Windows
    uvx labmcp-lakeshore --address tcp://192.168.1.40:7777 --check
    uvx labmcp-lakeshore --address GPIB0::12::INSTR --check
    

Add to your MCP client

Claude Code

claude mcp add cryostat -- uvx labmcp-lakeshore --address tcp://192.168.1.40:7777

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "cryostat": {
      "command": "uvx",
      "args": ["labmcp-lakeshore", "--address", "tcp://192.168.1.40:7777"]
    }
  }
}

Add --read-only to allow reading temperatures and heater status but block setpoint, ramp, range and PID changes (all_heaters_off stays available). For other clients, generate the snippet with uvx labmcp config lakeshore --address tcp://192.168.1.40:7777 --client vscode (also cursor, codex, claude-code).

Tools

ToolKindDescription
all_heaters_off🛑 safetyTurn every output off (heater range 0 on outputs 1-4), like the front-panel All Off key, and stop any running wait. Reports the read-back range of each output and all_off.
get_command_log👁 readReturn the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info👁 readReport which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_heater_status👁 readReport each output's control mode and input, heater range, output %, setpoint (and in kelvin), ramp state, PID values and heater errors (open/short). Reading a heater error clears it on the controller.
read_temperatures👁 readRead every (or the selected) sensor input: kelvin, raw sensor units, sensor type, input name and decoded reading status (invalid, under/overrange). Disabled inputs are listed with null readings.
reconnect🛑 safetyClose and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_heater_range⚠️ hazardSet an output's heater range (each step is ~10x more power). Anything above 0 lets the output heat: in closed loop as the PID demands, in open loop at the front-panel manual output. Refused above max_heater_range, or if the setpoint already programmed on a closed-loop, zone or warm-up output is above max_setpoint_k. Start with the lowest range that can reach the setpoint.
set_pid🎛 controlSet the P, I and D values of an output's control loop (Lake Shore conventions).
set_ramp🎛 controlTurn setpoint ramping on or off for an output's control loop and set the rate. With ramping on, the next setpoint change moves the setpoint gradually - gentler on samples and wiring.
set_setpoint⚠️ hazardSet the control setpoint of an output's loop in kelvin. If setpoint ramping is on, the setpoint moves toward the new value at the ramp rate. Heating only happens if the output is in closed-loop mode and its heater range is not off. Refused above max_setpoint_k.
wait_for_stable_temperature👁 readWait until the control input of output has stayed within tolerance_k of the setpoint (and the setpoint is no longer ramping) for stable_for_s, or until timeout_s. Returns whether it stabilised, the final temperature and a downsampled trace. Changes nothing.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

LimitDefaultMeaning
max_setpoint_k325 KHighest setpoint set_setpoint accepts (room temperature plus margin). set_heater_range also reads back the setpoint of a closed-loop, zone or warm-up output before letting it heat, so a higher setpoint entered on the front panel is refused too (as is a setpoint in sensor units, which cannot be checked). Raise it only if your stage, wiring and sensors are rated higher
max_heater_range3Highest heater range index. On the 335/336 3 = High (full power); on the 350 ranges go 1-5 in decade steps, so 3 is 1/100 of full power
max_wait_s3600 sLongest wait_for_stable_temperature call

Override at launch: --limit max_setpoint_k=420 --limit max_heater_range=2.

Example prompts

  • "Read all the temperatures and tell me if any sensor has an error."
  • "Ramp output 1 to 77 K at 2 K/min on the medium range, then wait until input A has been within 50 mK for 5 minutes."
  • "Step the sample from 10 K to 300 K in 10 K steps and tell me when each step is stable." (with max_setpoint_k high enough)
  • "What are the PID settings on loop 1? Reduce P to 30 and keep I and D."
  • "Something's wrong - turn all heaters off."

Notes

  • Setting a setpoint does not start heating; the heater range does. With a range above 0 an output heats as its PID loop demands (closed loop) or at the manual output (open loop). Output modes and control inputs are configured on the front panel; the server does not change them, since pointing a loop at the wrong sensor can cause a thermal runaway.
  • Setpoints are always given in kelvin. SETP uses the preferred units of the loop's control input: the server converts for Celsius and refuses when the input is set to sensor units.
  • Every command is followed by *ESR?; command (CME) and execution (EXE) errors are reported instead of being ignored. The server leaves at least 50 ms between messages, as the manuals require (--option min_interval_s=).
  • get_heater_status reads HTRST?, which clears a latched heater open/short error on the controller.
  • wait_for_stable_temperature needs the setpoint to have stopped ramping (RAMPST?) as well as the temperature to be in tolerance. all_heaters_off stops a running wait.
  • all_heaters_off sends RANGE n,0 to every output and reads it back, like the front-panel All Off key. Every output is tried even if another fails; all_off is true only when every output read back as off. It does not change setpoints or output modes. Consider also setting a hardware temperature limit (TLIMIT, front panel) as a last line of defence.
  • The 3062 scanner option (inputs D1-D5), zone tables, autotune, curves, alarms and relays are not exposed. The Model 372 AC resistance bridge was not verified and is refused at connect time.

Hardware verification

ModelFirmwareInterfaceVerified byDate
none yet: be the first

Comments

Markdown supported

New to MCP?

From what the protocol is to installing your first server, these answers cover most first questions.

An open protocol that defines how AI applications connect to external tools and data in a uniform way. Clients talk to the model; MCP servers provide tools, resources and prompt templates. They exchange standard messages, so one server can be reused by many clients.