mcpField
A
algo-mfg-spc

algo-mfg-spc

github.com/asgard-ai-platformData & databases24348 installsUpdated 21w ago
Repository

About algo-mfg-spc

A statistical process control skill for quality and production teams monitoring process stability over time. It guides control chart selection, limit calculation, and detection of out-of-control patterns while distinguishing control limits from specification limits.

Key features

  1. 01Choose charts for measurements or counts
  2. 02Calculate X-bar/R control limits
  3. 03Detect out-of-control points and patterns
  4. 04Validate time-ordered subgroup data
  5. 05Assess process stability

Use cases

  1. 01Monitor production processes for shifts
  2. 02Set statistical limits for quality measures
  3. 03Distinguish normal variation from special causes

Install

Copy the command and run it in a terminal.

$npx skills add https://github.com/asgard-ai-platform/skills --skill algo-mfg-spc

After installing, type/algo-mfg-spcin Claude Code to confirm it loaded.

Bundled files

References and scripts installed along with SKILL.md.

examples/
sample_scenario.md
references/
chart-constants.md
we-rules.md

Details

From the project README

Statistical Process Control

Overview

SPC uses control charts to monitor process stability over time. Upper and Lower Control Limits (UCL/LCL) are set at ±3σ from the process mean. Points within limits = common cause variation (stable). Points outside or showing patterns = special cause variation (investigate). Primary charts: X-bar/R, X-bar/S, I-MR, p-chart, c-chart.

When to Use

Trigger conditions:

  • Monitoring production process for stability and detecting shifts
  • Setting statistically-based control limits for quality metrics
  • Distinguishing normal variation from assignable causes

When NOT to use:

  • For process capability assessment (use Cpk)
  • For root cause analysis of known problems (use fishbone/5-why)

Algorithm

IRON LAW: Control Limits Are NOT Specification Limits
Control limits (±3σ) describe what the process IS doing.
Specification limits describe what the process SHOULD do.
A process can be in statistical control (stable) but still produce
out-of-spec products (incapable). Conversely, a capable process may
be out of control (drifting). Monitor control FIRST, then assess capability.
Phase 1: Input Validation

Collect: 25+ subgroups of measurements (5 per subgroup typical for X-bar/R). Verify: measurement system is adequate (gauge R&R < 10%), data collected in time order. Gate: Sufficient subgroups, time-ordered data, measurement system verified.

Phase 2: Core Algorithm

X-bar/R Chart (subgroup data):

  1. Compute subgroup means (X̄) and ranges (R)
  2. Compute grand mean (X̄̄) and average range (R̄)
  3. UCL_X̄ = X̄̄ + A₂×R̄, LCL_X̄ = X̄̄ - A₂×R̄ (A₂ from statistical tables by subgroup size)
  4. UCL_R = D₄×R̄, LCL_R = D₃×R̄
  5. Plot points, apply Western Electric rules for out-of-control signals
Phase 3: Verification

Check for: points outside limits, runs (7+ consecutive on one side), trends (7+ consecutive increasing/decreasing), 2 of 3 beyond 2σ, 4 of 5 beyond 1σ. Gate: Chart constructed, out-of-control signals identified.

Phase 4: Output

Return control chart data with signals and stability assessment.

Output Format

{
  "chart": {"type": "xbar_r", "center_line": 50.2, "ucl": 52.1, "lcl": 48.3},
  "signals": [{"subgroup": 18, "rule": "point_beyond_ucl", "value": 52.8}],
  "stability": "out_of_control",
  "metadata": {"subgroups": 30, "subgroup_size": 5}
}

Examples

Sample I/O

Input: 25 subgroups of 5 measurements each, all within ±3σ, no patterns Expected: Process in control. No signals triggered.

Edge Cases
InputExpectedWhy
One point just outside UCLSignal, but may be false alarm~0.27% chance per point even when in control
Gradual upward trendTrend rule triggeredProcess drifting, investigate
All points near centerSuspicious — check dataMay indicate data manipulation or measurement issue

Gotchas

  • Rational subgrouping: Subgroups must be collected under similar conditions (same shift, machine, operator). Poor subgrouping inflates within-group variation, making limits too wide.
  • Recalculating limits: Don't recalculate limits every time you add data. Establish limits from a stable baseline period and keep them fixed until a known process change.
  • Chart type selection: Variables data (measurements) → X-bar/R or I-MR. Attribute data (counts/proportions) → p-chart, np-chart, c-chart, u-chart. Wrong chart type = wrong limits.
  • Normality assumption: X-bar chart is robust to non-normality (central limit theorem). Individual charts (I-MR) require approximate normality — check with histogram.
  • Over-adjustment: Reacting to every small variation (tampering) INCREASES variability. Only investigate special cause signals, not common cause variation.

References

  • For control chart constants tables, see references/chart-constants.md
  • For Western Electric rules and pattern detection, see references/we-rules.md

Comments