mcpField
A
alterlab-opentrons

alterlab-opentrons

github.com/alterlab-ieuOther7866 installsUpdated 5w ago
Repository

About alterlab-opentrons

A skill for laboratory automation with Opentrons Flex or OT-2, guiding the creation of Python Protocol API v2 protocols. It covers pipetting, labware and deck configuration, hardware-module control, and simulation before execution.

Key features

  1. 01Write Python Protocol API v2 protocols
  2. 02Configure pipettes, labware, and decks
  3. 03Control temperature and other hardware modules
  4. 04Implement complex pipetting operations
  5. 05Simulate and test protocols

Use cases

  1. 01Automate liquid-handling workflows
  2. 02Set up PCR and serial dilution experiments
  3. 03Plan multi-channel pipetting operations
  4. 04Simulate protocols before robot execution

Install

Copy the command and run it in a terminal.

$npx skills add https://github.com/alterlab-ieu/alterlab-academic-skills --skill alterlab-opentrons

After installing, type/alterlab-opentronsin Claude Code to confirm it loaded.

Bundled files

References and scripts installed along with SKILL.md.

evals/
evals.json
references/
api_reference.md
hardware_modules.md
protocol_patterns.md
scripts/
basic_protocol_template.py
pcr_setup_template.py
serial_dilution_template.py

Details

From the project README

Opentrons Integration

Overview

Opentrons is a Python-based lab automation platform for Flex and OT-2 robots. Write Protocol API v2 protocols for liquid handling, control hardware modules (heater-shaker, thermocycler), manage labware, for automated pipetting workflows.

When to Use This Skill

This skill should be used when:

  • Writing Opentrons Protocol API v2 protocols in Python
  • Automating liquid handling workflows on Flex or OT-2 robots
  • Controlling hardware modules (temperature, magnetic, heater-shaker, thermocycler)
  • Setting up labware configurations and deck layouts
  • Implementing complex pipetting operations (serial dilutions, plate replication, PCR setup)
  • Managing tip usage and optimizing protocol efficiency
  • Working with multi-channel pipettes for 96-well plate operations
  • Simulating and testing protocols before robot execution
Does NOT Trigger
ScenarioUse Instead
One script driving Hamilton/Tecan liquid handlers, plate readers, or mixed vendorsalterlab-pylabrobot
Sending an experiment to a remote cloud lab (Ginkgo Cloud Lab RACs)alterlab-ginkgo-cloud
Protein expression/binding assays run by Adaptyv Bio's foundryalterlab-adaptyv
Publishing the written wet-lab protocol with a DOIalterlab-protocolsio

Core Capabilities

1. Protocol Structure and Metadata

Every Opentrons protocol follows a standard structure:

from opentrons import protocol_api

# Metadata (descriptive only here; apiLevel lives in requirements)
metadata = {
    'protocolName': 'My Protocol',
    'author': 'Name <[email protected]>',
    'description': 'Protocol description',
}

# apiLevel goes in exactly ONE of metadata/requirements: opentrons rejects a protocol
# that sets it in both. robotType is required for Flex protocols.
requirements = {
    'robotType': 'Flex',  # or 'OT-2'
    'apiLevel': '2.22'    # lowest level that has every feature you use (see below)
}

# Run function
def run(protocol: protocol_api.ProtocolContext):
    trash = protocol.load_trash_bin('A3')  # Flex: load a trash bin (or waste chute) before any drop_tip
    # Protocol commands go here

Key elements:

  • Import protocol_api from opentrons
  • metadata for name/author/description; requirements for robotType + apiLevel
  • Implement run() receiving a ProtocolContext; all protocol logic goes inside it
  • Flex protocols (API 2.16+) have no fixed trash: call protocol.load_trash_bin(slot) or protocol.load_waste_chute() first, or drop_tip() fails with NoTrashDefinedError

Choosing apiLevel: the latest is 2.29 (Flex robot software 9.1.1+; the opentrons 9.1.x package simulates up to it). Useful floors: 2.16 trash-bin/waste-chute loaders; 2.20 liquid-presence detection; 2.21 Absorbance Plate Reader; 2.22 Labware.load_liquid()/load_empty(); 2.24 liquid classes (transfer_with_liquid_class); 2.25 Flex Stacker; 2.27 concurrent module commands. Use the lowest level that covers your features so older robots can still run the protocol, and check it with opentrons_simulate.

2. Loading Hardware

Loading Instruments (Pipettes):

def run(protocol: protocol_api.ProtocolContext):
    # Load pipette on specific mount
    left_pipette = protocol.load_instrument(
        'flex_1channel_1000',  # Instrument name (Flex convention)
        'left',                # Mount: 'left' or 'right'
        tip_racks=[tip_rack]   # List of tip rack labware objects
    )

Common pipette load names (these are the exact instrument_name strings — do NOT invent p1000_single_flex-style names; Flex uses the flex_<channels>_<volume> convention):

  • Flex: flex_1channel_50, flex_1channel_1000, flex_8channel_50, flex_8channel_1000, flex_96channel_1000
  • OT-2: p20_single_gen2, p300_single_gen2, p1000_single_gen2, p20_multi_gen2, p300_multi_gen2

Loading Labware:

# Load labware directly on deck
plate = protocol.load_labware(
    'corning_96_wellplate_360ul_flat',  # Labware API name
    'D1',                                # Deck slot (Flex: A1-D3, OT-2: 1-11)
    label='Sample Plate'                 # Optional display label
)

# Load tip rack
tip_rack = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')

# Load labware on adapter
adapter = protocol.load_adapter('opentrons_flex_96_tiprack_adapter', 'B1')
tips = adapter.load_labware('opentrons_flex_96_tiprack_200ul')

Loading Modules:

# Temperature module (Flex + OT-2)
temp_module = protocol.load_module('temperature module gen2', 'D3')
temp_plate = temp_module.load_labware('corning_96_wellplate_360ul_flat')

# Heater-Shaker module (Flex + OT-2)
hs_module = protocol.load_module('heaterShakerModuleV1', 'D1')
hs_plate = hs_module.load_labware('corning_96_wellplate_360ul_flat')

# Thermocycler module (takes up specific slots automatically)
tc_module = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')

# Magnetic Module (OT-2 ONLY) — an active, motorized module. Flex does not
# support it; on Flex use the unpowered Magnetic Block instead (see below).
mag_module = protocol.load_module('magnetic module gen2', '1')  # OT-2 numeric slot
mag_plate = mag_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')

# Magnetic Block (Flex ONLY) — unpowered; labware is moved on/off it with the
# Gripper. There is no engage/disengage; it has no motors.
mag_block = protocol.load_module('magneticBlockV1', 'C2')
block_plate = mag_block.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
3. Liquid Handling Operations

Basic Operations:

# Pick up tip
pipette.pick_up_tip()

# Aspirate (draw liquid in)
pipette.aspirate(
    volume=100,           # Volume in µL
    location=source['A1'] # Well or location object
)

# Dispense (expel liquid)
pipette.dispense(
    volume=100,
    location=dest['B1']
)

# Drop tip
pipette.drop_tip()

# Return tip to rack
pipette.return_tip()

Complex Operations:

# Transfer (combines pick_up, aspirate, dispense, drop_tip)
pipette.transfer(
    volume=100,
    source=source_plate['A1'],
    dest=dest_plate['B1'],
    new_tip='always'  # 'always', 'once', or 'never'
)

# Distribute (one source to multiple destinations)
pipette.distribute(
    volume=50,
    source=reservoir['A1'],
    dest=[plate['A1'], plate['A2'], plate['A3']],
    new_tip='once'
)

# Consolidate (multiple sources to one destination)
pipette.consolidate(
    volume=50,
    source=[plate['A1'], plate['A2'], plate['A3']],
    dest=reservoir['A1'],
    new_tip='once'
)

Advanced Techniques:

# Mix (aspirate and dispense in same location)
pipette.mix(
    repetitions=3,
    volume=50,
    location=plate['A1']
)

# Air gap (prevent dripping)
pipette.aspirate(100, source['A1'])
pipette.air_gap(20)  # 20µL air gap
pipette.dispense(120, dest['A1'])

# Blow out (expel remaining liquid)
pipette.blow_out(location=dest['A1'].top())

# Touch tip (remove droplets on tip exterior)
pipette.touch_tip(location=plate['A1'])

Flow Rate Control:

# Set flow rates (µL/s)
pipette.flow_rate.aspirate = 150
pipette.flow_rate.dispense = 300
pipette.flow_rate.blow_out = 400
4. Accessing Wells and Locations

Well Access Methods:

# By name
well_a1 = plate['A1']

# By index
first_well = plate.wells()[0]

# All wells
all_wells = plate.wells()  # Returns list

# By rows
rows = plate.rows()  # Returns list of lists
row_a = plate.rows()[0]  # All wells in row A

# By columns
columns = plate.columns()  # Returns list of lists
column_1 = plate.columns()[0]  # All wells in column 1

# Wells by name (dictionary)
wells_dict = plate.wells_by_name()  # {'A1': Well, 'A2': Well, ...}

Location Methods:

# Passing a Well aspirates 1 mm above its bottom by default
pipette.aspirate(100, well)

# top()/bottom() are exact: z=0 is the top rim / the well bottom itself
pipette.dispense(100, well.top())        # at the rim
pipette.aspirate(100, well.top(z=-2))    # 2 mm below the rim
pipette.aspirate(100, well.bottom(z=2))  # 2 mm above the bottom (z=0 would touch it)

# Center of well
pipette.aspirate(100, well.center())
5. Hardware Module Control

Control temperature, magnetic, heater-shaker, thermocycler, and absorbance-reader modules. Each module context exposes its own set / wait / deactivate methods plus status properties (e.g. temp_module.set_temperature, hs_module.set_and_wait_for_shake_speed, tc_module.execute_profile). On Flex, the active Magnetic Module is replaced by the unpowered Magnetic Block (magneticBlockV1).

Full per-module code recipes (Temperature, Magnetic Module vs Flex Magnetic Block, Heater-Shaker, Thermocycler PCR cycling, Absorbance Plate Reader): see references/hardware_modules.md. The corresponding method/property tables are in references/api_reference.md.

6. Liquid Tracking and Labeling

Define Liquids:

# Define liquid types
water = protocol.define_liquid(
    name='Water',
    description='Ultrapure water',
    display_color='#0000FF'  # Hex color code
)

sample = protocol.define_liquid(
    name='Sample',
    description='Cell lysate sample',
    display_color='#FF0000'
)

Load Liquids into Wells (API 2.22+):

# Mark starting contents per labware (volumes in µL)
reservoir.load_liquid(wells=['A1'], volume=50000, liquid=water)
plate.load_liquid(wells=['A1', 'A2'], volume=100, liquid=sample)
plate.load_liquid_by_well({'A3': 50, 'A4': 75}, liquid=sample)

# Mark wells as empty
plate.load_empty(['B1', 'B2'])

Well.load_liquid(liquid, volume) still works but is deprecated from 2.22; there is no Well.load_empty().

7. Protocol Control and Utilities

Execution Control:

# Pause protocol
protocol.pause(msg='Replace tip box and resume')

# Delay
protocol.delay(seconds=60)
protocol.delay(minutes=5)

# Comment (appears in logs)
protocol.comment('Starting serial dilution')

# Home robot
protocol.home()

Conditional Logic:

# Check if simulating
if protocol.is_simulating():
    protocol.comment('Running in simulation mode')
else:
    protocol.comment('Running on actual robot')

Rail Lights (OT-2 and Flex, API 2.5+):

# Turn lights on
protocol.set_rail_lights(on=True)

# Turn lights off
protocol.set_rail_lights(on=False)
8. Multi-Channel and 8-Channel Pipetting

When using multi-channel pipettes:

# Load 8-channel pipette
multi_pipette = protocol.load_instrument(
    'p300_multi_gen2',
    'left',
    tip_racks=[tips]
)

# Access entire column with single well reference
multi_pipette.transfer(
    volume=100,
    source=source_plate['A1'],  # Accesses entire column 1
    dest=dest_plate['A1']       # Dispenses to entire column 1
)

# Column-wise with an 8-channel: target the row-A well of each column
for column_top in plate.rows()[0]:        # A1, A2, ... A12
    multi_pipette.transfer(100, reservoir['A1'], column_top)

With an 8-channel pipette, address row A wells only; targeting B1–H1 would put the other nozzles off the plate.

9. Common Protocol Patterns

Reusable end-to-end templates cover the most common workflows: serial dilution (diluent fill plus mix-after cascade across a row), plate replication (whole-plate wells()-to-wells() copy), and PCR setup (master-mix distribute, per-sample transfer, thermocycler cycling).

Full worked-example protocols for each pattern: see references/protocol_patterns.md. Runnable .py versions are in the scripts/ directory (serial_dilution_template.py, basic_protocol_template.py, pcr_setup_template.py).

Best Practices

  1. Always specify API level: Pin the lowest apiLevel that covers the features you use and that your robot's software accepts (confirm with opentrons_simulate)
  2. Use meaningful labels: Label labware for easier identification in logs
  3. Check tip availability: Ensure sufficient tips for protocol completion
  4. Add comments: Use protocol.comment() for debugging and logging
  5. Simulate first: Always test protocols in simulation before running on robot
  6. Handle errors gracefully: Add pauses for manual intervention when needed
  7. Consider timing: Use delays when protocols require incubation periods
  8. Track liquids: Use liquid tracking for better setup validation
  9. Optimize tip usage: Use new_tip='once' when appropriate to save tips
  10. Control flow rates: Adjust flow rates for viscous or volatile liquids

Troubleshooting

Common Issues:

  • Out of tips: Verify tip rack capacity matches protocol requirements
  • Labware collisions: Check deck layout for spatial conflicts
  • Volume errors: Ensure volumes don't exceed well or pipette capacities
  • Module not responding: Verify module is properly connected and firmware is updated
  • Inaccurate volumes: Calibrate pipettes and check for air bubbles
  • Protocol fails in simulation: Check API version compatibility and labware definitions

Resources

For detailed API documentation, see references/api_reference.md in this skill directory.

For example protocol templates, see scripts/ directory.

Part of the AlterLab Academic Skills suite.

Comments