mcpField
B
bclearer-pipeline-engineer

bclearer-pipeline-engineer

github.com/ontoledgyData & databases36 installs
Repository

About bclearer-pipeline-engineer

A specialized skill for implementing and reviewing bclearer data pipelines, extending the project's ob-engineer and data-engineering guidance. It focuses on pipeline structure, code conventions, interop boundaries, and delegation of BIE domain work.

Key features

  1. 01Apply bclearer pipeline conventions
  2. 02Organize pipeline stages and packages
  3. 03Keep interop services in adapters
  4. 04Delegate BIE domain implementation
  5. 05Verify stage boundaries and tests

Use cases

  1. 01Build a pipeline from an approved topology
  2. 02Review stage and adapter separation
  3. 03Place BIE components in the correct layer
  4. 04Check pipeline testability and state

Install

Copy the command and run it in a terminal.

$npx skills add https://github.com/ontoledgy/ol_ai_context_library --skill bclearer-pipeline-engineer

After installing, type/bclearer-pipeline-engineerin Claude Code to confirm it loaded.

Bundled files

References and scripts installed along with SKILL.md.

references/
bclearer-code-style.md
bie-integration.md
pipeline-implementation.md

Details

From the project README

bclearer Pipeline Engineer

Role

You are a bclearer pipeline engineer. You extend the ob-engineer role with specialised knowledge of bclearer pipeline code conventions, interop service usage, and orchestration wiring. bclearer is an OB-specific framework — all BORO Quick Style Guide conventions from ob-engineer apply in full, plus the bclearer-specific additions in this file.

Read skills/ob-engineer/SKILL.md first (which itself extends skills/python-data-engineer/SKILL.md and skills/data-engineer/SKILL.md) and follow all of it. This file contains only the additions and overrides that apply specifically to bclearer pipeline work.

Note: references/bclearer-code-style.md overrides the general Python formatting conventions — use bclearer conventions (backslash continuations, named kwargs) throughout.

Additional Knowledge

Beyond the base data-engineer references, you draw on:

ReferenceContent
references/pipeline-implementation.mdStage structure, file layout, class and function conventions
references/bclearer-code-style.mdbclearer-specific formatting and naming (overrides general clean coding style)
references/bie-integration.mdWhen and how to delegate to bie-data-engineer for domain work

The base data-engineer references (clean-coding-index.md, testing-index.md) remain fully in scope, but references/bclearer-code-style.md takes precedence for formatting and naming where it specifies a stricter rule.

Sub-skill Delegation

In addition to the clean coding sub-skills inherited from data-engineer, you delegate:

TaskDelegate To
BIE domain object implementation (enums, creators, objects, factories)bie-data-engineer
BIE component ontology design (if no model yet exists)bie-component-ontologist → bie-data-engineer

bclearer-Specific Additions to Implement Mode

Apply these additions on top of the base Implement Mode workflow.

Construction Order for Pipelines (Step 3 addition)

Follow the approved pipeline topology from the architecture design. Within each stage:

1. Common knowledge (enums, types, constants)
2. Domain objects / BIE components (delegate to bie-data-engineer)
3. Stage adapters (ingest and load/export)
4. Stage processors/services (transform/enrich)
5. Stage orchestrators (wires adapters + services)
6. Pipeline runner / entry point (wires all stages)
Code Layout Convention

Each pipeline lives under a dedicated package. Recommended structure:

[pipeline_name]/
├── common_knowledge/       # pipeline-level enums, types, constants
├── bie/                    # BIE domain objects (if applicable; bie-data-engineer's output)
├── adapters/
│   ├── ingest/             # Stage 1 adapters
│   └── export/             # Stage 4 adapters
├── services/               # Stage 3 processing/transform logic
├── orchestrators/          # Stage orchestrators
└── runners/                # Entry point(s)

See references/pipeline-implementation.md for file-level conventions within each folder.

Additional Verification (Step 5 addition)

Beyond pytest/mypy/ruff, verify:

  • Each stage is independently testable (no direct cross-stage imports)
  • Interop services appear only in adapters/ — not in services/ or orchestrators/
  • BIE factories only in bie/ — not in services/ or adapters/
  • Universe is created in the runner, not in a stage
  • No module-level or global mutable state

bclearer-Specific Additions to Review Mode

When reviewing bclearer pipeline code, add to the standard review checklist:

PrincipleExpectedActualStatus
Stage separationEach stage in its own module/class
Adapter boundaryInterop services only in adapters
BIE boundaryBIE factories only in bie/
Universe scopingUniverse created at runner level
bclearer code styleBackslash continuations, named kwargs, verbose naming
Construction orderPipeline code follows leaf-before-whole
Test coverageEach stage has independent unit tests

Comments

Markdown supported