mcpField
M
modbus-protocol

modbus-protocol

github.com/jnzader-vaultDevelopment092 installsUpdated 8w ago
Repository

About modbus-protocol

modbus-protocol is a skill guide for implementing Modbus TCP/RTU sensor communication in Rust, Go, and Python. It covers register operations, PLC address maps, data conversion, and polling practices for industrial integrations.

Key features

  1. 01Guidance for Rust, Go, and Python
  2. 02TCP/RTU register read and write patterns
  3. 03PLC address map examples
  4. 04Register-to-float conversion example
  5. 05Batch reads and connection reuse guidance

Use cases

  1. 01Read sensor values from industrial PLCs
  2. 02Build SCADA or gateway integrations
  3. 03Choose polling patterns for sensor data

Install

Copy the command and run it in a terminal.

$npx skills add https://github.com/jnzader-vault/project-starter-framework --skill modbus-protocol

After installing, type/modbus-protocolin Claude Code to confirm it loaded.

Details

From the project README

Modbus Protocol

Industrial Modbus TCP/RTU implementation for sensor communication

When to Use

  • Reading data from PLCs (Siemens, Allen-Bradley, Schneider)
  • Communicating with industrial sensors
  • Building SCADA/gateway systems
  • Implementing OT (Operational Technology) integrations

Stack

# Rust
tokio-modbus: "0.13+"

# Go
github.com/simonvetter/modbus: latest

# Python
pymodbus: "3.6+"

Modbus Fundamentals

Register Types
TypeAddress RangeAccessUse Case
Coils00001-09999R/WDigital outputs (on/off)
Discrete Inputs10001-19999RDigital inputs (read-only)
Input Registers30001-39999RAnalog inputs (16-bit)
Holding Registers40001-49999R/WConfiguration & data
Function Codes
CodeFunctionDescription
01Read CoilsRead multiple digital outputs
02Read Discrete InputsRead digital inputs
03Read Holding RegistersRead configuration registers
04Read Input RegistersRead analog inputs
05Write Single CoilSet single output
06Write Single RegisterWrite one register
16Write Multiple RegistersWrite block of registers

Rust Implementation

Client Setup
use tokio_modbus::prelude::*;
use tokio_modbus::client::tcp;
use std::net::SocketAddr;
use tokio::time::{timeout, Duration};

pub struct ModbusClient {
    ctx: client::Context,
    timeout_duration: Duration,
}

impl ModbusClient {
    pub async fn connect(addr: SocketAddr, slave_id: u8) -> Result<Self, ModbusError> {
        let ctx = tcp::connect_slave(addr, Slave(slave_id)).await?;
        Ok(Self { ctx, timeout_duration: Duration::from_secs(5) })
    }

    pub async fn read_holding_registers(&mut self, address: u16, count: u16) -> Result<Vec<u16>> {
        timeout(self.timeout_duration, self.ctx.read_holding_registers(address, count))
            .await
            .map_err(|_| ModbusError::Timeout)?
            .map_err(ModbusError::from)
    }

    pub async fn write_single_register(&mut self, address: u16, value: u16) -> Result<()> {
        timeout(self.timeout_duration, self.ctx.write_single_register(address, value))
            .await
            .map_err(|_| ModbusError::Timeout)?
            .map_err(ModbusError::from)
    }
}
Data Type Conversions
/// Two 16-bit registers to f32 (big-endian)
pub fn registers_to_f32(regs: &[u16]) -> f32 {
    let bytes = [
        (regs[0] >> 8) as u8, regs[0] as u8,
        (regs[1] >> 8) as u8, regs[1] as u8,
    ];
    f32::from_be_bytes(bytes)
}

/// Two 16-bit registers to f32 (little-endian, swapped)
pub fn registers_to_f32_le(regs: &[u16]) -> f32 {
    let bytes = [
        regs[1] as u8, (regs[1] >> 8) as u8,
        regs[0] as u8, (regs[0] >> 8) as u8,
    ];
    f32::from_le_bytes(bytes)
}

/// f32 to two 16-bit registers
pub fn f32_to_registers(value: f32) -> [u16; 2] {
    let bytes = value.to_be_bytes();
    [
        ((bytes[0] as u16) << 8) | (bytes[1] as u16),
        ((bytes[2] as u16) << 8) | (bytes[3] as u16),
    ]
}

/// Scale raw value to engineering units
pub fn scale_value(raw: u16, min_raw: u16, max_raw: u16, min_eng: f32, max_eng: f32) -> f32 {
    let range_raw = (max_raw - min_raw) as f32;
    let range_eng = max_eng - min_eng;
    let normalized = (raw - min_raw) as f32 / range_raw;
    min_eng + (normalized * range_eng)
}
Sensor Reader
#[derive(Debug, Clone)]
pub struct SensorConfig {
    pub id: String,
    pub name: String,
    pub address: u16,
    pub data_type: DataType,
    pub unit: String,
    pub scale: Option<Scale>,
}

#[derive(Debug, Clone)]
pub enum DataType {
    UInt16,
    Int16,
    Float32,
    Float32LE,
}

#[derive(Debug, Clone)]
pub struct SensorReading {
    pub sensor_id: String,
    pub value: f64,
    pub quality: u8,  // 192=Good, 128=Uncertain, 0=Bad
    pub timestamp: i64,
}

pub struct SensorReader {
    client: ModbusClient,
    sensors: Vec<SensorConfig>,
}

impl SensorReader {
    pub async fn read_sensor(&mut self, sensor: &SensorConfig) -> Result<SensorReading> {
        let count = match sensor.data_type {
            DataType::UInt16 | DataType::Int16 => 1,
            DataType::Float32 | DataType::Float32LE => 2,
        };

        let registers = self.client.read_holding_registers(sensor.address, count).await?;

        let raw_value: f64 = match sensor.data_type {
            DataType::UInt16 => registers[0] as f64,
            DataType::Int16 => (registers[0] as i16) as f64,
            DataType::Float32 => registers_to_f32(&registers) as f64,
            DataType::Float32LE => registers_to_f32_le(&registers) as f64,
        };

        let value = if let Some(scale) = &sensor.scale {
            scale_value(raw_value as u16, scale.min_raw, scale.max_raw, scale.min_eng, scale.max_eng) as f64
        } else {
            raw_value
        };

        Ok(SensorReading {
            sensor_id: sensor.id.clone(),
            value,
            quality: 192, // Good
            timestamp: chrono::Utc::now().timestamp_millis(),
        })
    }
}

Go Implementation

package modbus

import (
    "encoding/binary"
    "math"
    "sync"
    "time"

    "github.com/simonvetter/modbus"
)

type Client struct {
    client *modbus.ModbusClient
    mu     sync.Mutex
}

func NewClient(address string, slaveID uint8) (*Client, error) {
    client, err := modbus.NewClient(&modbus.ClientConfiguration{
        URL:     fmt.Sprintf("tcp://%s", address),
        Speed:   19200,
        Timeout: 5 * time.Second,
    })
    if err != nil { return nil, err }

    if err := client.Open(); err != nil { return nil, err }
    client.SetUnitId(slaveID)

    return &Client{client: client}, nil
}

func (c *Client) ReadHoldingRegisters(address, count uint16) ([]uint16, error) {
    c.mu.Lock()
    defer c.mu.Unlock()
    return c.client.ReadRegisters(address, count, modbus.HOLDING_REGISTER)
}

func RegistersToFloat32(regs []uint16) float32 {
    bytes := make([]byte, 4)
    binary.BigEndian.PutUint16(bytes[0:2], regs[0])
    binary.BigEndian.PutUint16(bytes[2:4], regs[1])
    return math.Float32frombits(binary.BigEndian.Uint32(bytes))
}

Python Implementation

from pymodbus.client import AsyncModbusTcpClient
from dataclasses import dataclass
import struct

@dataclass
class SensorConfig:
    id: str
    address: int
    data_type: str  # 'uint16', 'int16', 'float32'
    unit: str

class ModbusReader:
    def __init__(self, host: str, port: int = 502, slave_id: int = 1):
        self.host = host
        self.port = port
        self.slave_id = slave_id

    async def connect(self):
        self.client = AsyncModbusTcpClient(self.host, port=self.port)
        await self.client.connect()

    async def read_holding_registers(self, address: int, count: int):
        result = await self.client.read_holding_registers(address, count, slave=self.slave_id)
        return result.registers

    async def read_sensor(self, config: SensorConfig) -> float:
        count = 2 if 'float32' in config.data_type else 1
        regs = await self.read_holding_registers(config.address, count)

        if config.data_type == 'uint16':
            return regs[0]
        elif config.data_type == 'int16':
            return struct.unpack('>h', struct.pack('>H', regs[0]))[0]
        elif config.data_type == 'float32':
            bytes_data = struct.pack('>HH', regs[0], regs[1])
            return struct.unpack('>f', bytes_data)[0]

PLC Address Maps

Siemens S7-1200/1500
holding_registers:
  40001: DB1.DBD0   # Float, first double word in DB1
  40003: DB1.DBD4   # Float, second double word
  40005: MW100      # Word memory

coils:
  00001: Q0.0       # Output bit 0.0
  00002: Q0.1       # Output bit 0.1
Allen-Bradley ControlLogix
holding_registers:
  40001: N7:0       # Integer file
  40002: F8:0       # Float (uses 2 registers)
Schneider Modicon
holding_registers:
  40001: %MW0       # Memory word 0
  40003: %MF0       # Float (2 registers)

Error Handling

pub fn modbus_error_description(code: u8) -> &'static str {
    match code {
        0x01 => "Illegal Function",
        0x02 => "Illegal Data Address",
        0x03 => "Illegal Data Value",
        0x04 => "Slave Device Failure",
        0x05 => "Acknowledge",
        0x06 => "Slave Device Busy",
        _ => "Unknown Error",
    }
}

Best Practices

Batch Reads
// ✅ Single read for contiguous registers
client.read_holding_registers(40001, 10).await?;

// ❌ Multiple individual reads - slow!
for addr in 40001..40011 {
    client.read_holding_registers(addr, 1).await?;
}
Connection Reuse
// ✅ Reuse connection
let client = ModbusClient::connect(addr, slave_id).await?;
for _ in 0..100 {
    client.read_holding_registers(addr, count).await?;
}

// ❌ New connection per read
for _ in 0..100 {
    let client = ModbusClient::connect(addr, slave_id).await?;
    client.read_holding_registers(addr, count).await?;
}
Polling Intervals
Sensor TypeRecommended Interval
Vibration10-50ms
Temperature/Pressure500ms-1s
Level/Flow totals5-10s

Quick Reference

TaskRust
Read holdingctx.read_holding_registers(addr, count).await
Read inputctx.read_input_registers(addr, count).await
Write singlectx.write_single_register(addr, value).await
Write multiplectx.write_multiple_registers(addr, &values).await
Read coilsctx.read_coils(addr, count).await

Quality Codes (OPC UA)

CodeMeaning
192 (0xC0)Good
128 (0x80)Uncertain
0 (0x00)Bad

Resources

Related Skills

  • mqtt-rumqttc: Data forwarding to MQTT
  • tokio-async: Async polling patterns
  • timescaledb: Industrial data storage
  • rust-systems: Full Rust integration

Comments

Markdown supported